MODEL: JAS-1200 |
TOTAL
POWER: 1200
Watts |
INPUT VOLTAGES: 180 V to
260 VAC |
#
OF OUTPUTS: SINGLE |
Input
|
Input range |
180 V to 260 VAC or
255 V to 370 VAC |
Input frequency |
47 to 63 Hz |
Inrush current |
40 A peak max. @230
VAC; |
cold start @ 25 ¡æ |
|
Input current |
20 A Max. (RMS) @ 115 VAC |
Leakage current |
< 3.5 mA @ 50/60 Hz
260 VAC input |
Output |
Maximum power |
600 Watts |
Adjustment range |
5% |
Line regulation |
¡À 1% |
Load regulation |
¡À 2% |
OL protection |
105% to 135% above peak rating |
OV protection |
115% to 145% above nominal
output |
|
|
Isolation |
Input to output |
1.25 KV/1 min. |
Input to
FG |
1.25 KV/1 min. |
|
|
ENVIRONMENTAL |
Operating temp. |
0 ¡æ to 50 ¡æ ambient derate each
output at 4.0% per degree from 50 ¡æ to 60 ¡æ |
Storage temp. |
- 20 ¡æ to 75 ¡æ |
Operating humidity |
5% to 95% (non-condensing) |
Temp. coefficient |
0.04% per degree C |
MTBF |
> 100,000 hours at full load and 25 ¡æ ambient conditions
(Demonstrated) |
SPECIAL FEATURES |
¡ùWith parallel function |
¡ù High efficiency |
¡ù Low output ripple |
¡ù Remote sense |
¡ùAdjustment output |
¡ù Over voltage protection |
¡ù Overload protection |
¡ù 1 year warranty |
|
|
ORDERING INFORMATION |
MODEL NUMBER |
OUTPUT1
VOLTAGE |
MINIMUM
LOAD |
MINIMUM
LOAD
|
VOLTAGE
TOLERANCE
|
OPERATING
EFFICIENCY |
RIPPLE&NOISE
PEAK-PEAK
|
NOTES |
JAS-1200-12 |
12V |
0A |
50-100A |
1% |
80% (Typical) |
120mV |
6~12V |
JAS-1200-15 |
15V |
0A |
40-80A |
1% |
80% (Typical) |
150mV |
12~15V |
JAS-1200-24 |
24V |
0A |
25-50A |
1% |
85% (Typical) |
240mV |
15~24V |
JAS-1200-48 |
48V |
0A |
12.5-25A |
1% |
86% (Typical) |
480mV |
24~48V |
|
|