MODEL: JDS-40 |
TOTAL
POWER: 40
Watts |
INPUT VOLTAGES: 115 V to
230 VAC |
#
OF OUTPUTS: SINGLE |
Input
|
Input range |
90 V to 140 VDC or 180 V to 280 VDC |
Input frequency |
47 to 440 Hz |
Input current |
1 A Max. (RMS) @ 115 VDC |
Leakage current |
< 2.5 mA @ 50/60 Hz
280 VDC input |
Output |
Maximum power |
40 Watts for convection |
Adjustment range |
10% |
Line regulation |
¡À 0.5 % |
Load
regulation |
¡À 0.5 % |
OL protection |
110% to 145% above peak rating |
OV protection |
110% to 150% above nominal
output |
|
|
Isolation |
Input to output |
1.5 KV/1 min. |
Input to
FG |
1.5 KV/1 min. |
|
|
ENVIRONMENTAL |
Operating temp. |
0 ¡æ to 40 ¡æ ambient derate each
output at 4.0% per degree from 40 ¡æ to 60 ¡æ |
Storage temp. |
- 20 ¡æ to 75 ¡æ |
Operating humidity |
5% to 95% (non-condensing) |
Temp. coefficient |
0.02% per degree C |
MTBF |
> 80,000 hours at full load and 25 ¡æ ambient conditions
(Demonstrated) |
SPECIAL FEATURES |
¡ùNominal voltage input |
¡ù High efficiency |
¡ù Low output ripple |
¡ù Built-in EMI filter |
¡ùAdjustment output |
¡ù Over voltage protection |
¡ù Overload protection |
¡ù 1 year warranty |
|
|
ORDERING INFORMATION |
MODEL NUMBER |
OUTPUT1
VOLTAGE |
MINIMUM
LOAD |
MINIMUM
LOAD
|
VOLTAGE
TOLERANCE
|
OPERATING
EFFICIENCY |
RIPPLE&NOISE
PEAK-PEAK
|
NOTES |
JDS-40-5 |
5V |
0A |
6A |
5% |
70% (Typical) |
50mV |
3~6V |
JDS-40-9 |
9V |
0A |
4.5A |
3% |
72% (Typical) |
90mV |
6~9V |
JDS-40-13.8 |
13.8V |
0A |
2.9A |
3% |
73% (Typical) |
140mV |
9~13.8V |
JDS-40-18 |
18V |
0A |
2.3A |
3% |
74% (Typical) |
180mV |
13.8~18V |
JDS-40-24 |
24V |
0A |
1.68A |
2% |
75% (Typical) |
240mV |
18~24V |
JDS-40-48 |
48V |
0A |
0.83A |
1% |
77% (Typical) |
480mV |
24~48V |
|
|